Paramytha, Nadya Azza (2020) CHEST VIBRATOR. Diploma thesis, Poltekkes Kemenkes Surabaya.
Text
Cover.pdf Download (115kB) |
|
Text
LEMBAR PENGESAHAN DAN PERETUJUAN.pdf Restricted to Repository staff only Download (3MB) |
|
Text
ABSTRAK BAHASA INDONESIA.pdf Download (28kB) |
|
Text
ABSTRAK BAHASA INGGRIS.pdf Download (28kB) |
|
Text
KATA PENGANTAR.pdf Restricted to Repository staff only Download (120kB) |
|
Text
DAFTAR ISI.pdf Download (16kB) |
|
Text
DAFTAR GAMBAR.pdf Restricted to Repository staff only Download (33kB) |
|
Text
DAFTAR TABEL.pdf Restricted to Repository staff only Download (28kB) |
|
Text
BAB I.pdf Restricted to Repository staff only Download (107kB) |
|
Text
BAB II.pdf Restricted to Repository staff only Download (423kB) |
|
Text
BAB III.pdf Restricted to Repository staff only Download (107kB) |
|
Text
BAB IV.pdf Restricted to Repository staff only Download (302kB) |
|
Text
BAB V.pdf Restricted to Repository staff only Download (147kB) |
|
Text
BAB VI.pdf Restricted to Repository staff only Download (33kB) |
|
Text
Daftar Pustaka.pdf Download (103kB) |
|
Text
LAMPIRAN.pdf Restricted to Repository staff only Download (361kB) |
|
Text
List Program.pdf Restricted to Repository staff only Download (154kB) |
|
Text
JURNAL TEKNOKES P27838017009.pdf Restricted to Repository staff only Download (323kB) |
|
Text
Rangkaian Keseluruhan.pdf Restricted to Repository staff only Download (199kB) |
Abstract
Chest Vibrator is a chest therapy tool that is used to help bronchitis patients reduce the accumulation of secretions / sputum in the lungs. The purpose of this research is to design a Chest Vibrator device that focuses on the treatment of bronchitis and utilizes one of the techniques of chest physiotherapy that is vibration using a 12V DC motor and media therapy using a paddle. The research contribution is that the system can provide therapeutic treatment to the chest in accordance with the frequency and time set in the driver circuit using IC NE 555 which is used to drive a 12V DC motor with 3 frequency selections, 30, 40, and 50 Hz and use 3 timer selections ie 3-5 minutes which will be displayed on the LCD in a counter down. Data processing is performed by Arduino as data processing and controlling the work of the timer. The making of this module uses a pre-experimental method and the type of one group post test design research is that the researcher only sees the results without measuring the previous situation and there is no control group. Data retrieval is done by comparing the value of the settings on the module with the measurement results on the oscilloscope. Obtained the results of frequency data retrieval with a minimum error value of ± 0.008% and a maximum error value of ± 0.02%. This module can help as a support for the treatment of bronchitis with an age range of 12-45 years.
Item Type: | Thesis (Diploma) |
---|---|
Contributors: | Contribution Contributor NIDN/NIDK UNSPECIFIED Lamidi, Lamidi nidn4008047601 UNSPECIFIED Kholiq, Abd. nidn4022057501 |
Additional Information: | 11KTI2020013 |
Uncontrolled Keywords: | Bronchitis; Frequency; Chest Vibration; Chest Therapy Tool; TDC Motor; Fisioterapi; IC NE 555; LCD; Arduino |
Subjects: | R Medicine > Medical Electronics > Biomedical Engineering R Medicine > Medical Electronics > Clinical Engineering |
Divisions: | Poltekkes Kemenkes Surabaya > Jurusan Teknologi Elektromedik > Program Studi DIII Teknologi Elektro-medis |