EFISIENSI PENURUNAN KADAR AMONIA (NH3) MENGGUNAKAN METODE BUBBLE AERATOR DENGAN VARIASI WAKTU AERASI PADA LIMBAH CAIR RS BHAKTI PERSADA KECAMATAN BARAT KABUPATEN MAGETAN

PAWESTRI, SYIFA AFIFAH (2024) EFISIENSI PENURUNAN KADAR AMONIA (NH3) MENGGUNAKAN METODE BUBBLE AERATOR DENGAN VARIASI WAKTU AERASI PADA LIMBAH CAIR RS BHAKTI PERSADA KECAMATAN BARAT KABUPATEN MAGETAN. Diploma thesis, Poltekkes Kemenkes Surabaya.

[thumbnail of 1. HALAMAN JUDUL COVER.pdf] Text
1. HALAMAN JUDUL COVER.pdf

Download (149kB)
[thumbnail of 2. HALAMAN PENGESAHAN.pdf] Text
2. HALAMAN PENGESAHAN.pdf
Restricted to Repository staff only

Download (328kB)
[thumbnail of 3. ABSTRAK.pdf] Text
3. ABSTRAK.pdf

Download (74kB)
[thumbnail of 4. HALAMAN BIODATA.pdf] Text
4. HALAMAN BIODATA.pdf

Download (41kB)
[thumbnail of 5. KATA PENGANTAR, DAFTAR ISI, DAFTAR ISTILAH, DLL.pdf] Text
5. KATA PENGANTAR, DAFTAR ISI, DAFTAR ISTILAH, DLL.pdf

Download (157kB)
[thumbnail of 6. BAB I.pdf] Text
6. BAB I.pdf

Download (178kB)
[thumbnail of 7. BAB II.pdf] Text
7. BAB II.pdf

Download (191kB)
[thumbnail of 8. BAB III.pdf] Text
8. BAB III.pdf
Restricted to Repository staff only

Download (200kB)
[thumbnail of 9. BAB IV.pdf] Text
9. BAB IV.pdf
Restricted to Repository staff only

Download (305kB)
[thumbnail of 10. BAB V.pdf] Text
10. BAB V.pdf
Restricted to Repository staff only

Download (117kB)
[thumbnail of 11. BAB VI.pdf] Text
11. BAB VI.pdf
Restricted to Repository staff only

Download (89kB)
[thumbnail of 12. DAFTAR PUSTAKA.pdf] Text
12. DAFTAR PUSTAKA.pdf

Download (109kB)
[thumbnail of 13. LAMPIRAN.pdf] Text
13. LAMPIRAN.pdf

Download (2MB)
[thumbnail of JURNAL KTI_SYIFA AFIFAH PAWESTRI_P27833221072.pdf] Text
JURNAL KTI_SYIFA AFIFAH PAWESTRI_P27833221072.pdf
Restricted to Repository staff only

Download (411kB)

Abstract

ABSTRAK Penelitian ini dilatarbelakangi oleh permasalahan tingginya kadar amonia pada outlet limbah cair RS Bhakti Persada yang jika dibuang ke badan air akan mengganggu kehidupan dan ekosistem perairan. Tujuan penelitian ini untuk mengukur penurunan kadar amonia dengan variasi waktu aerasi 2 jam, 4 jam, dan 6 jam pada limbah cair RS Bhakti Persada. Metode pada penelitian ini adalah kuantitatif. Data yang didapatkan berasal dari hasil pemeriksaan kadar amonia oleh laboratorium kimia. Pada penelitian ini akan ada 3 bak tanpa dilakukan aerasi dan 3 bak treatment yang berupa aerasi menggunakan blower udara, dari ke-3 bak treatment tersebut akan diberi waktu kontak selama 2 jam, 4 jam, dan 6 jam yang kemudian akan diambil sampel untuk diperiksakan ke laboratorium. Hasil dari penelitian penurunan kadar amonia dengan variasi waktu aerasi 2 jam rata-ratanya 0,758 mg/l tidak terjadi penurunan dan tidak signifikan. Untuk variasi waktu aerasi 4 jam rata-ratanya 0,746 mg/l terjadi penurunan namun tidak signifikan dengan efisiensi 3,610%. Pada variasi waktu aerasi 6 jam rata-ratanya 0,732 mg/l dengan efisiensi 5,400%, menurut uji paired sig 2-tailed (0,000) < α (0,050) maka terjadi penurunan kadar amonia yang signifikan. Disarankan pada penelitian selanjutnya untuk menambah waktu aerasi dan menambahkan treatment lain. Kata kunci: Amonia, waktu aerasi, penurunan. EFFICIENCY OF REDUCING AMONIA (NH3) LEVELS USING THE BUBBLE AERATOR METHOD WITH VARIATIONS IN AERATION TIME IN LIQUID WASTE OF BHAKTI PERSADA HOSPITAL, BARAT DISTRICT, MAGETAN DISTRICT Syifa Afifah Pawestri1, Hery Koesmantoro2, Karno3, Sri Poerwati4 MINISTRY OF HEALTH OF THE REPUBLIC OF INDONESIA POLTEKKES KEMENKES SURABAYA DEPARTMENT OF ENVIRONMENTAL HEALTH SANITATION PROGRAM D-III MAGETAN CAMPUS Email: syifapawestri1@gmail.com ABSTRACT This research was motivated by the problem of high levels of ammonia at the liquid waste outlet of Bhakti Persada Hospital which, if discharged into water bodies, would disrupt aquatic life and ecosystems. The aim of this research was to measure the reduction in ammonia levels with variations in aeration time of 2 hours, 4 hours and 6 hours in Bhakti Persada Hospital liquid waste. The method in this research is quantitative. The data obtained comes from the results of checking ammonia levels by a chemistry laboratory. In this research there will be 3 treatment tanks without aeration and 3 treatment tanks which include aeration using an air blower. From these 3 treatment tanks, contact time will be given for 2 hours, 4 hours and 6 hours and then samples will be taken for examination. laboratory. The results of the research on reducing ammonia levels with variations in aeration time of 2 hours averaged 0,758 mg/l, there was no decrease and it was not significant. For variations in aeration time of 4 hours, the average decrease was 0,746 mg/l, but it was not significant with an efficiency of 3,610%. At a variation of aeration time of 6 hours the average was 0,732 mg/l with an efficiency of 5,400%, according to the paired sig 2-tailed (0.00) < α (0.05) test, there was a significant decrease in ammonia levels. It is recommended that in future research increase the aeration time and add other treatments. Key words: Ammonia, aeration time, reduction.

Item Type: Thesis (Diploma)
Contributors:
Contribution
Contributor
NIDN/NIDK
UNSPECIFIED
KOESMANTORO, HERY
nidn4026116102
UNSPECIFIED
KARNO, KARNO
nidn4009115901
UNSPECIFIED
POERWATI, SRI
nidn4028056901
Additional Information: 1454/KTI/2024 / 10KTI2024063
Uncontrolled Keywords: Amonia, waktu aerasi, penurunan
Subjects: T Technology > TD Environmental technology. Sanitary engineering
Divisions: Poltekkes Kemenkes Surabaya > Jurusan Kesehatan Lingkungan > Program Studi DIII Sanitasi Magetan
Depositing User: Endah Widyastuti
Date Deposited: 07 Mar 2025 02:58
Last Modified: 07 Mar 2025 02:58
URI: http://repo.poltekkesdepkes-sby.ac.id/id/eprint/10187

Actions (login required)

View Item View Item