Asrori’, Ach Jiddan (2023) Keakurasian sensor occlusion SENO257 pada infusion device analyzer 2 channel tampil TFT. Skripsi thesis, Politeknik Kesehatan Kemenkes Surabaya.
Text
1. Cover.pdf Download (86kB) |
|
Text
2. Halaman Persetujuan Pembimbing.pdf Restricted to Repository staff only Download (156kB) |
|
Text
3. Halaman Pengesahan Penguji.pdf Restricted to Repository staff only Download (153kB) |
|
Text
4. Abstrak.pdf Download (128kB) |
|
Text
5. Kata Pengantar.pdf Restricted to Repository staff only Download (196kB) |
|
Text
6. Daftar Isi.pdf Download (36kB) |
|
Text
7. Daftar Tabel.pdf Download (30kB) |
|
Text
8. Daftar Gambar.pdf Download (31kB) |
|
Text
9. Bab 1.pdf Restricted to Repository staff only Download (113kB) |
|
Text
10. Bab 2.pdf Restricted to Repository staff only Download (308kB) |
|
Text
11. Bab 3.pdf Restricted to Repository staff only Download (137kB) |
|
Text
12. Bab 4.pdf Restricted to Repository staff only Download (270kB) |
|
Text
13. Bab 5.pdf Restricted to Repository staff only Download (157kB) |
|
Text
14. Bab 6.pdf Restricted to Repository staff only Download (36kB) |
|
Text
15. Daftar Pustaka.pdf Download (97kB) |
|
Text
16. Lampiran.pdf Restricted to Repository staff only Download (47kB) |
|
Text
17. Artikel.pdf Restricted to Repository staff only Download (288kB) |
Abstract
Both the syringe pump and the infusion pump are used to administer fluids or medications into a blood vessel in a steady, timed stream. Infusion pumps and syringe pumps often have issues with obstruction or occlusion. Because of a blockage in the infusion system, the incoming medication fluid does not continuously flow. The ECRI-recommended upper limit for occlusion is 20 PSI. Calibration must be performed at least once a year to assure accuracy. The goal of this study is to determine how well the pressure sensor works for measuring occlusion on the Infusion Device Analyzer's second channel of visual display. This investigation has dual channels, allowing for simultaneous tool calibration. This module's design incorporates a Water Pressure Sensor for occlusion measurement and a solenoid valve for pressure modeling. When pressure is applied to the sensor, data is sent to an Arduino for analysis. After the pressure readings have been taken, they are graphed and shown in numerical form on a 7- inch TFT LCD before being saved to an SD card.
Item Type: | Thesis (Skripsi) |
---|---|
Contributors: | Contribution Contributor NIDN/NIDK UNSPECIFIED Yulianto, Endro nidn4017077601 UNSPECIFIED Rahmawati, Triana nidn4023068101 |
Additional Information: | 11SKR20230001 |
Uncontrolled Keywords: | Calibration, Occlusion, Syringepump, Infusepump |
Subjects: | R Medicine > Medical Electronics |
Divisions: | Poltekkes Kemenkes Surabaya > Jurusan Teknologi Elektromedik > Program Studi Sarjana Terapan Teknologi Rekayasa Elektro-medis |
Depositing User: | Misnawar |
Date Deposited: | 26 Jan 2024 01:18 |
Last Modified: | 26 Jan 2024 01:18 |
URI: | http://repo.poltekkesdepkes-sby.ac.id/id/eprint/7751 |