Paramartha, I Kadek Nova and Hamzah, Torib and Utomo, Bedjo and Luthfiyah, Sari and Ozdemdrcd, Emre (2022) Lost Data and Transmitting Speed Analysison Incubator Analyzer Based IoT Technology. International Journal of Advanced Health Science and Technology, 2 (1). pp. 39-46. ISSN 2808-6422 (e), 2829-3037 (p)

[thumbnail of document-3.pdf.pdf] Text
document-3.pdf.pdf

Download (2MB)

Abstract

The importance of the readiness of the baby incubator for critical infant patients who are treated intensively encourages health technicians to carry out regular maintenance and calibration to overcome theproblem of equipment malfunctions. Critical infant patients are babies who are treated in the NICU (Neonatal Intensive Care Unit) due to premature birth or babies using incubators are diagnosed with abnormalities ordiseases, this situation makes babies need tools for survival, especially in the first month. Calibrating temperature control is very necessary for the incubator. In addition to temperature, it is necessary to control humidity so that the baby's respiratory system is in optimal condition. In addition, it is also equipped with anoise sensor to ensure that the noise in the baby incubator room is appropriate. From the above problems, atool for temperature testing was made using a DHT22 sensor with five measurement points, humidity with alevel of 30% RH-60% RH and noise with a range of 30dB-60db to ensure the tool functions properly equipped with a lost data testing system and delivery speed. using internet access with thing speak display.This research resulted in the design of a calibration tool with three parameters, namely the temperature setting at 33ºC the smallest error percentage is 0% and the largest error is 0.96%, and at the temperature setting 35ºC the smallest error percentage is 0.28% and the largest error is 4 .1%, humidity with an error percentage of0.82% and noise with an error percentage of 0.93%. The drawback in using the Thingspeak application isthat there is a limit on the channel ID, which can only display 8 readings, while the minimum time lag is 20seconds. For the MAX4466 noise sensor, there are shortcomings, namely the accuracy in readings is not good.

Item Type: Article
Uncontrolled Keywords: Internet of Things (IoT), Lost Data, Delivery Speed, Three Parameters
Subjects: R Medicine > Medical Electronics > Clinical Engineering
R Medicine > Medical Electronics
Divisions: Poltekkes Kemenkes Surabaya > Pusat Penelitan dan Pengabdian Masyarakat > Pubikasi
Depositing User: Nanik Indra Putri Sari
Date Deposited: 12 Apr 2023 02:31
Last Modified: 17 Apr 2023 07:12
URI: http://repo.poltekkesdepkes-sby.ac.id/id/eprint/6665

Actions (login required)

View Item View Item